X-ray computed tomography (CT) imaging constitutes one of the most widely used diagnostic tools in radiology today with nearly 85 million CT examinations performed in the U.S in 2011. CT imparts a relatively high amount of radiation dose to the patient compared to other x-ray imaging modalities and as a result of this fact, coupled with its popularity, CT is currently the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the relationship between dose and image quality. All things being held equal, reducing the dose degrades image quality and can impact the diagnostic value of the CT examination.

A recent push from the medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose reduction potential of these new technologies in an objective and rigorous manner. Establishing these dose reduction potentials requires precise and clinically relevant metrics of CT image quality, as well as practical and efficient methodologies to measure such metrics on real CT systems. The currently established methodologies for assessing CT image quality are not appropriate to assess modern CT scanners that have implemented those aforementioned dose reduction technologies.

Thus the purpose of this doctoral project was to develop, assess, and implement new phantoms, image quality metrics, analysis techniques, and modeling tools that are appropriate for image quality assessment of modern clinical CT systems. The project developed image quality assessment methods in the context of three distinct paradigms, (a) uniform phantoms, (b) textured phantoms, and (c) clinical images.

The work in this dissertation used the “task-based” definition of image quality. That is, image quality was broadly defined as the effectiveness by which an image can be used for its intended task. Under this definition, any assessment of image quality requires three components: (1) A well defined imaging task (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).

First, this task-based image quality paradigm was implemented using a novel multi-sized phantom platform (with uniform background) developed specifically to assess modern CT systems (Mercury Phantom, v3.0, Duke University). A comprehensive evaluation was performed on a state-of-the-art CT system (SOMATOM Definition Force, Siemens Healthcare) in terms of noise, resolution, and detectability as a function of patient size, dose, tube energy (i.e., kVp), automatic exposure control, and reconstruction algorithm (i.e., Filtered Back-Projection– FPB vs Advanced Modeled Iterative Reconstruction– ADMIRE). A mathematical observer model (i.e., computer detection algorithm) was implemented and used as the basis of image quality comparisons. It was found that image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose (increase in detectability index by up to 163% depending on iterative strength). The use of automatic exposure control resulted in more consistent image quality with changing phantom size.

Based on those results, the dose reduction potential of ADMIRE was further assessed specifically for the task of detecting small (<=6 mm) low-contrast (<=20 HU) lesions. A new low-contrast detectability phantom (with uniform background) was designed and fabricated using a multi-material 3D printer. The phantom was imaged at multiple dose levels and images were reconstructed with FBP and ADMIRE. Human perception experiments were performed to measure the detection accuracy from FBP and ADMIRE images. It was found that ADMIRE had equivalent performance to FBP at 56% less dose.

Using the same image data as the previous study, a number of different mathematical observer models were implemented to assess which models would result in image quality metrics that best correlated with human detection performance. The models included naïve simple metrics of image quality such as contrast-to-noise ratio (CNR) and more sophisticated observer models such as the non-prewhitening matched filter observer model family and the channelized Hotelling observer model family. It was found that non-prewhitening matched filter observers and the channelized Hotelling observers both correlated strongly with human performance. Conversely, CNR was found to not correlate strongly with human performance, especially when comparing different reconstruction algorithms.

The uniform background phantoms used in the previous studies provided a good first-order approximation of image quality. However, due to their simplicity and due to the complexity of iterative reconstruction algorithms, it is possible that such phantoms are not fully adequate to assess the clinical impact of iterative algorithms because patient images obviously do not have smooth uniform backgrounds. To test this hypothesis, two textured phantoms (classified as gross texture and fine texture) and a uniform phantom of similar size were built and imaged on a SOMATOM Flash scanner (Siemens Healthcare). Images were reconstructed using FBP and a Sinogram Affirmed Iterative Reconstruction (SAFIRE). Using an image subtraction technique, quantum noise was measured in all images of each phantom. It was found that in FBP, the noise was independent of the background (textured vs uniform). However, for SAFIRE, noise increased by up to 44% in the textured phantoms compared to the uniform phantom. As a result, the noise reduction from SAFIRE was found to be up to 66% in the uniform phantom but as low as 29% in the textured phantoms. Based on this result, it clear that further investigation was needed into to understand the impact that background texture has on image quality when iterative reconstruction algorithms are used.

To further investigate this phenomenon with more realistic textures, two anthropomorphic textured phantoms were designed to mimic lung vasculature and fatty soft tissue texture. The phantoms (along with a corresponding uniform phantom) were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Scans were repeated a total of 50 times in order to get ensemble statistics of the noise. A novel method of estimating the noise power spectrum (NPS) from irregularly shaped ROIs was developed. It was found that SAFIRE images had highly locally non-stationary noise patterns with pixels near edges having higher noise than pixels in more uniform regions. Compared to FBP, SAFIRE images had 60% less noise on average in uniform regions for edge pixels, noise was between 20% higher and 40% lower. The noise texture (i.e., NPS) was also highly dependent on the background texture for SAFIRE. Therefore, it was concluded that quantum noise properties in the uniform phantoms are not representative of those in patients for iterative reconstruction algorithms and texture should be considered when assessing image quality of iterative algorithms.

The move beyond just assessing noise properties in textured phantoms towards assessing detectability, a series of new phantoms were designed specifically to measure low-contrast detectability in the presence of background texture. The textures used were optimized to match the texture in the liver regions actual patient CT images using a genetic algorithm. The so called “Clustured Lumpy Background” texture synthesis framework was used to generate the modeled texture. Three textured phantoms and a corresponding uniform phantom were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Images were reconstructed with FBP and SAFIRE and analyzed using a multi-slice channelized Hotelling observer to measure detectability and the dose reduction potential of SAFIRE based on the uniform and textured phantoms. It was found that at the same dose, the improvement in detectability from SAFIRE (compared to FBP) was higher when measured in a uniform phantom compared to textured phantoms.

The final trajectory of this project aimed at developing methods to mathematically model lesions, as a means to help assess image quality directly from patient images. The mathematical modeling framework is first presented. The models describe a lesion’s morphology in terms of size, shape, contrast, and edge profile as an analytical equation. The models can be voxelized and inserted into patient images to create so-called “hybrid” images. These hybrid images can then be used to assess detectability or estimability with the advantage that the ground truth of the lesion morphology and location is known exactly. Based on this framework, a series of liver lesions, lung nodules, and kidney stones were modeled based on images of real lesions. The lesion models were virtually inserted into patient images to create a database of hybrid images to go along with the original database of real lesion images. ROI images from each database were assessed by radiologists in a blinded fashion to determine the realism of the hybrid images. It was found that the radiologists could not readily distinguish between real and virtual lesion images (area under the ROC curve was 0.55). This study provided evidence that the proposed mathematical lesion modeling framework could produce reasonably realistic lesion images.

Based on that result, two studies were conducted which demonstrated the utility of the lesion models. The first study used the modeling framework as a measurement tool to determine how dose and reconstruction algorithm affected the quantitative analysis of liver lesions, lung nodules, and renal stones in terms of their size, shape, attenuation, edge profile, and texture features. The same database of real lesion images used in the previous study was used for this study. That database contained images of the same patient at 2 dose levels (50% and 100%) along with 3 reconstruction algorithms from a GE 750HD CT system (GE Healthcare). The algorithms in question were FBP, Adaptive Statistical Iterative Reconstruction (ASiR), and Model-Based Iterative Reconstruction (MBIR). A total of 23 quantitative features were extracted from the lesions under each condition. It was found that both dose and reconstruction algorithm had a statistically significant effect on the feature measurements. In particular, radiation dose affected five, three, and four of the 23 features (related to lesion size, conspicuity, and pixel-value distribution) for liver lesions, lung nodules, and renal stones, respectively. MBIR significantly affected 9, 11, and 15 of the 23 features (including size, attenuation, and texture features) for liver lesions, lung nodules, and renal stones, respectively. Lesion texture was not significantly affected by radiation dose.

The second study demonstrating the utility of the lesion modeling framework focused on assessing detectability of very low-contrast liver lesions in abdominal imaging. Specifically, detectability was assessed as a function of dose and reconstruction algorithm. As part of a parallel clinical trial, images from 21 patients were collected at 6 dose levels per patient on a SOMATOM Flash scanner. Subtle liver lesion models (contrast = -15 HU) were inserted into the raw projection data from the patient scans. The projections were then reconstructed with FBP and SAFIRE (strength 5). Also, lesion-less images were reconstructed. Noise, contrast, CNR, and detectability index of an observer model (non-prewhitening matched filter) were assessed. It was found that SAFIRE reduced noise by 52%, reduced contrast by 12%, increased CNR by 87%. and increased detectability index by 65% compared to FBP. Further, a 2AFC human perception experiment was performed to assess the dose reduction potential of SAFIRE, which was found to be 22% compared to the standard of care dose.

In conclusion, this dissertation provides to the scientific community a series of new methodologies, phantoms, analysis techniques, and modeling tools that can be used to rigorously assess image quality from modern CT systems. Specifically, methods to properly evaluate iterative reconstruction have been developed and are expected to aid in the safe clinical implementation of dose reduction technologies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The diagnosis of Alzheimer's disease (AD) remains difficult. Lack of diagnostic certainty or possible distress related to a positive result from diagnostic testing could limit the application of new testing technologies. The objective of this paper is to quantify respondents' preferences for obtaining AD diagnostic tests and to estimate the perceived value of AD test information. METHODS: Discrete-choice experiment and contingent-valuation questions were administered to respondents in Germany and the United Kingdom. Choice data were analyzed by using random-parameters logit. A probit model characterized respondents who were not willing to take a test. RESULTS: Most respondents indicated a positive value for AD diagnostic test information. Respondents who indicated an interest in testing preferred brain imaging without the use of radioactive markers. German respondents had relatively lower money-equivalent values for test features compared with respondents in the United Kingdom. CONCLUSIONS: Respondents preferred less invasive diagnostic procedures and tests with higher accuracy and expressed a willingness to pay up to €700 to receive a less invasive test with the highest accuracy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The World Health Organization (WHO 2003) recognizes 3 endometrial stromal neoplasms: noninvasive endometrial stromal nodule and the 2 invasive neoplasms, endometrial stromal sarcoma (ESS), low grade and undifferentiated endometrial sarcoma (UES). It is important to note that the WHO 2003 does not define moderate atypia (an important differentiating diagnostic criterion for ESS, low grade and UES), nor does it discuss its significance. Moreover, studies on reproducibility and additional prognostic value of other diagnostic features in large are lacking. Using strict definitions, we analyzed the agreement between routine and expert-review necrosis and nuclear atypia in 91 invasive endometrial stromal neoplasias (IESN). The overall 5-year and 10-year recurrence-free survival rate estimates of the 91 IESN patients were 82% and 75%, respectively. Necrosis was well reproducible, and nuclear atypia was reasonably well reproducible. The 10-year recurrence-free survival rates for necrosis absent/inconspicuous versus prominent were 89% and 45% (P<0.001) and those for review-confirmed none/mild, moderate, severe atypia were 90%, 30%, and <20% (P<0.00001). Therefore, cases with moderate/severe atypia should be grouped together. Nuclear atypia and necrosis had independent prognostic values (Cox regression). Once these features were taken into account, no other feature had an independent additional prognostic value, including mitotic count. Using "none/mild atypia, necrosis absent/inconspicuous" as ESS, low grade versus "moderate/severe atypia present or necrosis present" as UES resulted in 68 ESS, low grade and 23 UES cases with disease-specific overall mortality-free survival of 99% versus 48% (P<0.00001, hazard ratio=45.4). When strictly defined microscopic criteria are used, the WHO 2003 diagnoses of ESS, low grade and UES are well reproducible and prognostically strong. © 2012 International Society of Gynecological Pathologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The activation parameters and the rate constants of the water-exchange reactions of Mn(III)TE-2-PyP(5+) (meso-tetrakis(N-ethylpyridinium-2-yl)porphyrin) as cationic, Mn(III)TnHex-2-PyP(5+) (meso-tetrakis(N-n-hexylpyridinium-2-yl)porphyrin) as sterically shielded cationic, and Mn(III)TSPP(3-) (meso-tetrakis(4-sulfonatophenyl)porphyrin) as anionic manganese(iii) porphyrins were determined from the temperature dependence of (17)O NMR relaxation rates. The rate constants at 298 K were obtained as 4.12 x 10(6) s(-1), 5.73 x 10(6) s(-1), and 2.74 x 10(7) s(-1), respectively. On the basis of the determined entropies of activation, an interchange-dissociative mechanism (I(d)) was proposed for the cationic complexes (DeltaS(double dagger) = approximately 0 J mol(-1) K(-1)) whereas a limiting dissociative mechanism (D) was proposed for Mn(III)TSPP(3-) complex (DeltaS(double dagger) = +79 J mol(-1) K(-1)). The obtained water exchange rate of Mn(III)TSPP(3-) corresponded well to the previously assumed value used by Koenig et al. (S. H. Koenig, R. D. Brown and M. Spiller, Magn. Reson. Med., 1987, 4, 52-260) to simulate the (1)H NMRD curves, therefore the measured value supports the theory developed for explaining the anomalous relaxivity of Mn(III)TSPP(3-) complex. A magnitude of the obtained water-exchange rate constants further confirms the suggested inner sphere electron transfer mechanism for the reactions of the two positively charged Mn(iii) porphyrins with the various biologically important oxygen and nitrogen reactive species. Due to the high biological and clinical relevance of the reactions that occur at the metal site of the studied Mn(iii) porphyrins, the determination of water exchange rates advanced our insight into their efficacy and mechanism of action, and in turn should impact their further development for both diagnostic (imaging) and therapeutic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Why do beliefs that attach different amounts of status to different categories of people become consensually held by the members of a society? We show that two microlevel mechanisms, in combination, imply a system-level tendency toward consensual status beliefs about a nominal characteristic. (1) Status belief diffusion: a person who has no status belief about a characteristic can acquire a status belief about that characteristic from interacting with one or more people who have that status belief. (2) Status belief loss: a person who has a status belief about a characteristic can lose that belief from interacting with one or more people who have the opposite status belief. These mechanisms imply that opposite status beliefs will tend to be lost at equal rates and will tend to be acquired at rates proportional to their prevalence. Therefore, if a status belief ever becomes more prevalent than its opposite, it will increase in prevalence until every person holds it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One year after the introduction of Information and Communication Technology (ICT) to support diagnostic imaging at our hospital, clinicians had faster and better access to radiology reports and images; direct access to Computed Tomography (CT) reports in the Electronic Medical Record (EMR) was particularly popular. The objective of this study was to determine whether improvements in radiology reporting and clinical access to diagnostic imaging information one year after the ICT introduction were associated with a reduction in the length of patients' hospital stays (LOS). METHODS: Data describing hospital stays and diagnostic imaging were collected retrospectively from the EMR during periods of equal duration before and one year after the introduction of ICT. The post-ICT period was chosen because of the documented improvement in clinical access to radiology results during that period. The data set was randomly split into an exploratory part used to establish the hypotheses, and a confirmatory part. The data was used to compare the pre-ICT and post-ICT status, but also to compare differences between groups. RESULTS: There was no general reduction in LOS one year after ICT introduction. However, there was a 25% reduction for one group - patients with CT scans. This group was heterogeneous, covering 445 different primary discharge diagnoses. Analyses of subgroups were performed to reduce the impact of this divergence. CONCLUSION: Our results did not indicate that improved access to radiology results reduced the patients' LOS. There was, however, a significant reduction in LOS for patients undergoing CT scans. Given the clinicians' interest in CT reports and the results of the subgroup analyses, it is likely that improved access to CT reports contributed to this reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper challenges the common assumption that economic agents know their tastes. After reviewing previous research showing that valuation of ordinary products and experiences can be manipulated by non-normative cues, we present three studies showing that in some cases people do not have a pre-existing sense of whether an experience is good or bad-even when they have experienced a sample of it. © 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Humans make decisions in highly complex physical, economic and social environments. In order to adaptively choose, the human brain has to learn about- and attend to- sensory cues that provide information about the potential outcome of different courses of action. Here I present three event-related potential (ERP) studies, in which I evaluated the role of the interactions between attention and reward learning in economic decision-making. I focused my analyses on three ERP components (Chap. 1): (1) the N2pc, an early lateralized ERP response reflecting the lateralized focus of visual; (2) the feedback-related negativity (FRN), which reflects the process by which the brain extracts utility from feedback; and (3) the P300 (P3), which reflects the amount of attention devoted to feedback-processing. I found that learned stimulus-reward associations can influence the rapid allocation of attention (N2pc) towards outcome-predicting cues, and that differences in this attention allocation process are associated with individual differences in economic decision performance (Chap. 2). Such individual differences were also linked to differences in neural responses reflecting the amount of attention devoted to processing monetary outcomes (P3) (Chap. 3). Finally, the relative amount of attention devoted to processing rewards for oneself versus others (as reflected by the P3) predicted both charitable giving and self-reported engagement in real-life altruistic behaviors across individuals (Chap. 4). Overall, these findings indicate that attention and reward processing interact and can influence each other in the brain. Moreover, they indicate that individual differences in economic choice behavior are associated both with biases in the manner in which attention is drawn towards sensory cues that inform subsequent choices, and with biases in the way that attention is allocated to learn from the outcomes of recent choices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Diagnostic imaging represents the fastest growing segment of costs in the US health system. This study investigated the cost-effectiveness of alternative diagnostic approaches to meniscus tears of the knee, a highly prevalent disease that traditionally relies on MRI as part of the diagnostic strategy. PURPOSE: To identify the most efficient strategy for the diagnosis of meniscus tears. STUDY DESIGN: Economic and decision analysis; Level of evidence, 1. METHODS: A simple-decision model run as a cost-utility analysis was constructed to assess the value added by MRI in various combinations with patient history and physical examination (H&P). The model examined traumatic and degenerative tears in 2 distinct settings: primary care and orthopaedic sports medicine clinic. Strategies were compared using the incremental cost-effectiveness ratio (ICER). RESULTS: In both practice settings, H&P alone was widely preferred for degenerative meniscus tears. Performing MRI to confirm a positive H&P was preferred for traumatic tears in both practice settings, with a willingness to pay of less than US$50,000 per quality-adjusted life-year. Performing an MRI for all patients was not preferred in any reasonable clinical scenario. The prevalence of a meniscus tear in a clinician's patient population was influential. For traumatic tears, MRI to confirm a positive H&P was preferred when prevalence was less than 46.7%, with H&P preferred above that. For degenerative tears, H&P was preferred until the prevalence reaches 74.2%, and then MRI to confirm a negative was the preferred strategy. In both settings, MRI to confirm positive physical examination led to more than a 10-fold lower rate of unnecessary surgeries than did any other strategy, while MRI to confirm negative physical examination led to a 2.08 and 2.26 higher rate than H&P alone in primary care and orthopaedic clinics, respectively. CONCLUSION: For all practitioners, H&P is the preferred strategy for the suspected degenerative meniscus tear. An MRI to confirm a positive H&P is preferred for traumatic tears for all practitioners. Consideration should be given to implementing alternative diagnostic strategies as well as enhancing provider education in physical examination skills to improve the reliability of H&P as a diagnostic test. CLINICAL RELEVANCE: Alternative diagnostic strategies that do not include the use of MRI may result in decreased health care costs without harm to the patient and could possibly reduce unnecessary procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary globalization has been marked by significant shifts in the organization and governance of global industries. In the 1970s and 1980s, one such shift was characterized by the emergence of buyer-driven and producer-driven commodity chains. In the early 2000s, a more differentiated typology of governance structures was introduced, which focused on new types of coordination in global value chains (GVCs). Today the organization of the global economy is entering another phase, with transformations that are reshaping the governance structures of both GVCs and global capitalism at various levels: (1) the end of the Washington Consensus and the rise of contending centers of economic and political power; (2) a combination of geographic consolidation and value chain concentration in the global supply base, which, in some cases, is shifting bargaining power from lead firms in GVCs to large suppliers in developing economies; (3) new patterns of strategic coordination among value chain actors; (4) a shift in the end markets of many GVCs accelerated by the economic crisis of 2008-09, which is redefining regional geographies of investment and trade; and (5) a diffusion of the GVC approach to major international donor agencies, which is prompting a reformulation of established development paradigms. © 2013 © 2013 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rise of private food standards has brought forth an ongoing debate about whether they work as a barrier for smallholders and hinder poverty reduction in developing countries. This paper uses a global value chain approach to explain the relationship between value chain structure and agrifood safety and quality standards and to discuss the challenges and possibilities this entails for the upgrading of smallholders. It maps four potential value chain scenarios depending on the degree of concentration in the markets for agrifood supply (farmers and manufacturers) and demand (supermarkets and other food retailers) and discusses the impact of lead firms and key intermediaries on smallholders in different chain situations. Each scenario is illustrated with case examples. Theoretical and policy issues are discussed, along with proposals for future research in terms of industry structure, private governance, and sustainable value chains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Accurate detection of persons in need of mental healthcare is crucial to reduce the treatment gap between psychiatric burden and service use in low- and middle-income (LAMI) countries. AIMS: To evaluate the accuracy of a community-based proactive case-finding strategy (Community Informant Detection Tool, CIDT), involving pictorial vignettes, designed to initiate pathways for mental health treatment in primary care settings. METHOD: Community informants using the CIDT identified screen positive (n = 110) and negative persons (n = 85). Participants were then administered the Composite International Diagnostic Interview (CIDI). RESULTS: The CIDT has a positive predictive value of 0.64 (0.68 for adults only) and a negative predictive value of 0.93 (0.91 for adults only). CONCLUSIONS: The CIDT has promising detection properties for psychiatric caseness. Further research should investigate its potential to increase demand for, and access to, mental health services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

© 2014, Springer Science+Business Media Dordrecht.The burgeoning literature on global value chains (GVCs) has recast our understanding of how industrial clusters are shaped by their ties to the international economy, but within this context, the role played by corporate social responsibility (CSR) continues to evolve. New research in the past decade allows us to better understand how CSR is linked to industrial clusters and GVCs. With geographic production and trade patterns in many industries becoming concentrated in the global South, lead firms in GVCs have been under growing pressure to link economic and social upgrading in more integrated forms of CSR. This is leading to a confluence of “private governance” (corporate codes of conduct and monitoring), “social governance” (civil society pressure on business from labor organizations and non-governmental organizations), and “public governance” (government policies to support gains by labor groups and environmental activists). This new form of “synergistic governance” is illustrated with evidence from recent studies of GVCs and industrial clusters, as well as advances in theorizing about new patterns of governance in GVCs and clusters.